![]() ![]() TM 1-2840-252-23-2
2-39
REMOVE OUTPUT SHAFT SEAL AND HOUSING ASSEMBLY
2-39
NOTE
Before removing output shaft seal and
housing assembly, check for evidence of oil
leakage from seal If evidence of leakage is
found, have aircraft powerplant inspector
examine seal housing assembly in
accordance with Task 2-41
1. Remove lockwire and six bolts (1)
2. Install three handling tools (T26) (2) in three threaded
holes (3) in output shaft seal and housing assembly (4).