Click here to make tpub.com your Home Page

Page Title: Power Supply
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Back
Internal Oscillator
Up
TB-9-6625-2182-35 Signal Generator SG-1207/U (Hewlett-Packard Model 8642M) Manual
Next
Final Procedure

TB 9-6625-2182-35
Table 22. Internal Oscillator Distortion
Audio analyzer
Test instrument
distortion indications
DATA
<(%)
modulated frequency
20
Hz
0.02
100
Hz
0.02
1
kHz
0.02
10
kHz
0.02
15
kHz
0.02
30
kHz
0.15
100
kHz
0.15
(4) Press TI ENTRY ­ MOD FREQ pushbutton and enter DATA modulated
frequency for each row in table 23. Set audio analyzer to measure frequency. Audio
analyzer will indicate within limits listed in table 23.
Table 23. Internal Oscillator Frequency
Test instrument
Audio analyzer
DATA
indications
modulated
(Hz)
frequency
settings
Min
Max
20
Hz
19.6
20.4
100
Hz
98
102
1
kHz
980
1020
10
kHz
9800
10200
50
kHz
49000
51000
100
kHz
98000
102000
(5) Disconnect audio analyzer from TI OUTPUT MOD.
b. Adjustments. No adjustments can be made.
19. Power Supply
a. Performance Check
NOTE
Do not perform power supply check if all other parameters are
within tolerance.
(1) Deenergize TI and remove top cover.
(2) Set POWER switch ON and allow sufficient time to warm-up.
(3) Connect multimeter HI INPUT to test points listed in table 24 and connect LO
INPUT to chassis ground.
(4) If multimeter does not indicate within specifications listed in table 24, perform b below:
(5) Remove test leads and deenergize TI.
(6) Replace TI cover.