Click here to make tpub.com your Home Page

Page Title: Table 17. Incidental AM
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Back
Frequency Modulation
Up
TB-9-6625-2182-35 Signal Generator SG-1207/U (Hewlett-Packard Model 8642M) Manual
Next
Phase Modulation

TB 9-6625-2182-35
(f)
ENTRY - FM.
(g)
DATA ­ 20 kHz.
(h)
MODULATION SOURCE - EXT DC.
(i)
MOD - FREQ.
(j)
DATA - 1 kHz.
(k)
SHIFT.
(l)
ENTRY ­ MOD OUT.
(m)
DATA ­ ( +1V).
(3) Set measuring receiver to measure AM with a 300 Hz high pass filter and a
3 kHz low pass filter.
(4) Measuring receiver will indicate within limits specified in table 17.
Table 17. Incidental AM
Measuring
receiver
Peak
indication
deviation
Modulation
Carrier
<%
kHz
rate
frequency
1 GHz
1 kHz
20
0.3
(5) Set measuring receiver to measure FM with all filters off.
(6) Set audio analyzer to measure distortion.
(7) Press TI pushbuttons as listed in (a) through (f) below:
(a)
ENTRY - FREQ.
(b)
DATA - 250 MHz.
(c)
ENTRY - AMPTD.
(d)
DATA - (+10 dBm).
(e)
ENTRY - FM.
(f)
DATA - 300 kHz.
(8) Press ENTRY ­ MOD FREQ pushbutton and enter DATA modulated
frequency for each row listed in table 18. Distortion measurement on audio analyzer will
indicate within limits specified.
Table 18. Audio FM Distortion
Test instrument
Audio analyzer distortion
DATA
indications
modulated frequency
(%)
20  Hz
2
400  Hz
2
1  kHz
2
100  kHz
2
(9) Perform steps (a) through (d) below for each row in table 19:
(a) Press TI ENTRY - FREQ pushbutton and enter DATA carrier frequency as listed.
(b) Press TI ENTRY ­ MOD FREQ pushbutton and enter DATA modulation
frequency as listed.
15