TM   5-4320-304-14 TM   08922A-14/1 Table   3-1.   Operator   Troubleshooting-Continued MALFUNCTION TEST   OR   INSPECTION CORRECTIVE   ACTION Step  3. Step  4. Step  5. Check   air   cleaner   restriction   indicator. If  red  band  appears  in  window  of  restriction  indicator,  and  rain  hood  is  not blocked  and  no  damage  to  system  components  is  found,  replace  air  filter (para 3-4). Check  for  loose  connections  or  a  restricted  or  damaged  line  between  fuel  lift pump  and  tank,  between  fuel  lift  pump  and  injection  pump,  and  between injection   pump   and   injector. Tighten  loose  connections. maintenance. Check  for  restrictions  in  suction Report  damaged  lines  to  organizational or discharge hoses or hose end. Clean  away  debris.  If  hoses  are  severely 5.   ENGINE   STOPS   RUNNING Step  1. Step  2. damaged  or  restricted,  replace. Death or serious injury could occur if fuel is not handled carefully. Use in a well-ventilated area away from open flame, arcing equipment, ignition sources, heaters, or excessive heat. Engines must be turned off and cool before refueling.  Use  proper  refueling  procedures  and equipment to avoid spillage. Do not run en- gines near open fuel containers. Always store fuel  in  proper,  marked  containers.  DO  NOT SMOKE. Check   for   Insufficient   fuel   supply. Fill   fuel   tank. Check  air  cleaner  restriction  indicator  for  indication  of  restrictions  or  excessive dirt   in   air   filter. If  red  band  appears  in  window  of  restriction  indicator,  and  rain  hood  is  not blocked  and  no  damage  to  system  components  is  found,  replace  air  filter (para 3-4). 3-5

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business