BURNER, FUEL FEEDER TUBE, BOTTOM SHIELD, AND MIXING CHAMBER AND AIR SHUTTER ASSEMBLY -cont

TM 10-7360-204-13&P Change 11          4-9 b.   Replacement.   Replace bad generator with one of the two sparegenerators (1) attached to the unit. (1)   Remove the two screws (2) and  (3) that attach the spare generator (1) to the burner unit. NOTE Replace  screws to secure generator brackets  to prevent damage to bracket  during  handling  of  burner  unit,  and  until  a  new  spare generator is received. (2)   Remove spare generator (1). Remove plastic orifice protective cap (5) and plastic inlet protector plug (6) if not previously removed. NOTE The  plastic  shipping  caps  and  plugs  should  be  removed  from  the spare generator assemblies when they are installed on the Burner Unit.  This will eliminate melting of the plastic caps and plugs during burner operation. (3) Check that fuel orifice nut  (4) is installed and tight on generator tube. Insert orifice end of generator into mixing chamber opening and slide generator to the rear until orifice and mixing chamber mesh. (4) Insert generatorinlet into fuel feed tube (7) and tighten nut. 4-9.3 BURNER, FUEL FEEDER TUBE, BOTTOM SHIELD, AND MIXING CHAMBER AND AIR SHUTTER ASSEMBLY.    a.   General. The purpose of the burner is to evenly distribute the flame. Fuel vapors pass through the mixing chamber and out the burner slots and the vapor is ignited. The slots must be clean and free of any foreign matter. The bottom shield helps to deflect the heat from the fuel tanks.    b.   Preliminary Requiremeuts.         (1)   Remove top shield (para 4-9.1.)         (2)   Remove generator and clean and replace fuel feed tube (para 4-9.2).