TM  10-7360-204-13&P TABLE  3-1.  OPERATOR  TROUBLESHOOTING–Continued MALFUNCTION TEST OR INSPECTION CORRECTIVE  ACTION 2. 3. PREHEATER FAILS TO IGNITE. Step  1.  Orifice  is  clogged. Clean  orifice. Step  2.  Low  air  pressure. Pressurize  fuel  system. Step  3.  Dirty  or  contaminated  fuel. Shut  down–clean  and  replace  fuel. BURNER FAILS TO IGNITE. Step 1. Low  air  pressure. Pressurize fuel system. Step  2.  Insufficient  fuel  supply. Fill fuel tank. Step  3.  Generator  insufficiently  preheated. Preheat generator for longer period of time. Step 4. Feed tube assembly missing, clogged or dented. Shut down-allow to cool–clean feed tube assembly or have replaced. 4. YELLOW  BURNER  FLAME. Step   1.   Air   control   shutter   improperly   adjusted. Adjust   shutter. Step  2.  Mixing  chamber  flooded. Turn  off  generator  flame  valve,  allow  flame  to  burn  out,  and  relight  burner. 5.  BLUE  BURNER  FLAME. Air control shutter improperly adjusted. Adjust  shutter. 6.  BURNER  FLAME  TOO  LOW. Step  1.  Flame  valve  adjusted  too  low. Open flame valve slightly. Step  2.  Insufficient  fuel  supply  or  defective  generator. Allow  to  cool-replace  fuel  and/or  generator. NOTE Do not overfdl, 8 quarts (7.6 liters) required. Step  3.  Generator  flame  valve  orifice  unit  is  partly  clogged. Turn off flame valve, allow flame to burn out, and relight the burner. 7.  BURNER  FLAME  UNEVEN. Slots in burner arm clogged. Clean  burner  slots. 3-2 Change 4

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing