OVEN SHUTDOWN CONTROLS
Up
TM-10-7360-201-10 Bakery Plant Trailer Mounted Field Models M-1945 M-1945-50 M-1945-53 and M-534-68 Manual
Next
Section IV. OPERATION UNDER UNUSUAL CONDITIONS

TM 10-7360-201-10
2-10.
SHUTTING DOWN EQUIPMENT - Continued
a.
Mixing and Makeup Machinery.
(1)
Disconnect electrical connections (para. 2-9a).
(2)
Perform after-operation services (para. 2-7).
b.
Oven.
WARNING
After oven burner is shut off let the blower run several
minutes after burner stops firing to clear out gas fumes.
(1)
Set fuel metering float valve adjusting screw (1) at position 0 and turn stop screw knob (3) clockwise to OFF
position.
(2)
Turn off bypass valve (4) if it has been used to bypass magnetic valve (5).
(3)
Close fuel tank shutoff gate valve (6).
(4)
Let blower run several minutes after burner stops firing to clear out gas fumes.
(5)
Push oven burner toggle switch (7) to OFF position.
6)
Push oven light toggle switch (8) to OFF position.
(7)
Push oven motor manual starter switch (9) to OFF position. For model M533 bakery oven, press stop button to
stop oven blower motor.
(8)
Disconnect electrical connections (para. 2-9a).
(9)
Perform after-operation services (para. 2-7).
c.
Proofing Cabinet.
(1)
Disconnect electrical connections (para. 2-9a).
(2)
Perform after-operation services (para. 2-7).
d.
Flour Sifter.
(1)
Disconnect electrical connections (para 2-9a).
(2)
Burn reject bag to destroy weevils sifted from flour.
(3)
Perform after-operation services (para. 2-7).
e.
Generator Set.
(1)
Push in the main switch OFF.
(2)
Allow engine to idle for a few minutes to cool it.
(3)
Turn magneto switch to OFF position to stop engine.
(4)
Be sure all switches are in OFF position.
(5)
Disconnect electrical connections (para. 2-9a).
(6)
Perform after-operation (a) services listed in TM5-6115-321-12 for the generator set.
2-53