Click here to make tpub.com your Home Page

Page Title: 2 Section Refrigerator
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Back
20 Cubic Foot Refrigerator
Up
TM-10-7310-282-10 Force Provider Food Service Equipment Manual
Next
3 Section Refrigerator

TM 10-7310-282-10
0003 00
2 Section Refrigerator
Capacity ................................................................................................................................ 48 ft3 (1.36 m3)
Width ................................................................................................................................... 52 in (132.1 cm)
Length ............................................................................................................................... 35 ½ in (90.2 cm)
Height .............................................................................................................................. 82 ¼ in (208.9 cm)
Weight ................................................................................................................................... 350 lb (159 kg)
Refrigerant ........................................................................................................................................ R-134a
Electrical requirements ....................................................................................................................115VAC
The 2 section refrigerator (1) is a glass front, two door unit employing a conventional air cooled
refrigeration system. In this system, refrigerant gas is taken into a compressor and discharged at high
pressure into an air cooled condenser. Heat is removed from the refrigerant in the condenser and
dissipated into the air. The refrigerant cools enough in the condenser to liquefy. Liquid refrigerant is
conducted to a metering device, which sprays liquid refrigerant into the evaporator. The evaporator
operates at much lower pressure than the condenser, and the refrigerant flashes off into gas, absorbing
heat in the process. The warm gas exiting the evaporator is then returned to the compressor to begin the
cycle again.
A thermostat monitors the cabinet temperature, and cycles the refrigeration system on and off as
required. The thermostat is adjustable, but does not normally require any adjustment.
The 2 section refrigerator may be equipped with an electric defrost system, incorporating a timer and an
electric heating grid attached to the evaporator. The timer can be set to operate the defrost grid at any
time desired. Models without an electric defrost system rely on the cabinet air to defrost the evaporator
when the refrigeration system has cycled off.