Figure 5-2.  Two-Inch Valved Unisex Coupling
Up
TM-10-4330-237-13P Filter-Separator Water Liquid Fuel for Advanced Aviation Forwarded Area Refueling System (AAFARS) Model E72FS-Z001 Manual
Next
(8) Install O-ring

TM 10-4330-237-13&P a. Inspection. (1) Inspect all metal parts for dings, gouges, abrasions etc.  On all parts except the ball (9), use 320 grit paper to smooth and remove sharp edges.  If ball (9) is damaged (scratched, gouged, etc.) it should be replaced. (2) Check  the  groove  (round  bottom)  in  the  inlet  for  burrs  on  the  corners.    If  groove  is  worn  such  that  burrs exist, use 320 grit paper to smooth and remove sharp edges. (3) Inspect the small spring-loaded continuity ball (26) located in the face of the unit.  Push the ball in and be sure that it pops back into place.  If the ball does not pop back freely, electrical continuity is lost and static discharge is possible.  Replace entire coupling if continuity ball does not pop back out. (4) Inspect screw (5) and handle (8) for damage.  If either part is bent, replace it. WARNING · Dry  cleaning  solvent,  P-D-680,  Type  HI,  is  potentially  dangerous  to  personnel and   property.      Eye   and   skin   protection   is   required.      Avoid   repeated   and prolonged skin contact.  Wash hands immediately after exposure.  Do not use near open flame or excessive heat.  Use only in areas with good ventilation. · Rubber gloves should be worn when handling fueling system components due to the toxic effects of some fuel additives and the dry cleaning solvent. (5) Make certain  all  components  are  clean  and  free  from  oil,  grease  or  dirt.    Wash  all  parts  with  an  approved dry cleaning solvent and dry thoroughly with a clean, lint-free, cloth. b. Assembly. NOTE During assembly, apply a light coat of petrolatum to O-rings before installation. (1) If interlock mechanism was removed, install lockout pin (23), spring (24) and screw (22) in two-inch valved unisex coupling (3). CAUTION The   lugs   used   in   the   AAFARS   unisex   couplings   are   made   of   two   different materials,  stainless  steel  and  aluminum.    The  two-inch  suction  hoses,  two-inch wyes and all three-inch unisex couplings have stainless steel long and short lugs in  the  coupling  body;  three-inch  dust  caps  have  aluminum  lugs.  The  discharge hoses,  tees,  crosses,  manifolds  and  elbow  unisex  couplings  have  aluminum  long and short lugs.  Verify the correct lugs by using the parts listing in Appendix C of this manual. (2) If lugs (19 or 20) were removed, install lugs (19 or 20) and screws (21). (3) If removed, install bumper (18) such that tapered edge is facing toward the housing. (4) If  dust  cap  cable  (17)  was  cut  to  remove  it  from  dust  cap  (2),  thread  cable  through  dust  cap  (2)  forming  a loop.  Use a sleeve (27) and crimp loose end of cable to itself. (5) Install O-ring (16) and downstream seal (15) in two-inch valved unisex coupling (3). (6) Install O-ring (14) on shaft (13) and install shaft from inside two-inch valved unisex coupling (3). (7) Using screws (4) install handle assembly (1) on shaft (13).  Rotate handle assembly to closed position. 5-7