Figure 4-9.  Unisex Coupling Dust Cap Replacement
Up
TM-10-4330-237-13P Filter-Separator Water Liquid Fuel for Advanced Aviation Forwarded Area Refueling System (AAFARS) Model E72FS-Z001 Manual
Next
Figure 4-10.  Unisex Coupling Bumper and Lug Replacement.

TM 10-4330-237-13&P b.   Assembly.  (Figure 4-9) WARNING Rubber  gloves  should  be  worn  when  handling  fueling  system  components  due  to the toxic effects of some fuel additives. (1) If  necessary  to  install  attaching  cable  (3)  on  3-inch  unisex  coupling  dust  cap  (1),  thread  attaching  cable  (3) through split ring (5) on dust cap (1).  If necessary to install attaching cable (3) on 2-inch unisex coupling dust cap (1), thread attaching cable (3) through dust cap (1) forming a loop.  Use a sleeve (6) and crimp loose end of cable to itself. (2) Install dust cap (1) and attaching cable (3) to unisex coupling (2) by threading attaching cable (3) through split ring (4) on unisex coupling (2). (3) Install dust cap (1) onto unisex coupling (2). 4.13  REPLACE UNISEX COUPLING BUMPER. This task consists of: a.  Removal b.  Assembly INITIAL SET-UP: Tools: Materials/Parts Required: Tool kit, General Mechanics None (Appendix B, Section III, Item 1) Chemical and Oil Protective Gloves (Appendix B, Section III, Item 2) General Safety Requirements: Equipment Condition: Liquid fuel filter-separator removed from WARNING AAFARS.  (TM 10-4930-250-13&P, para.  2.8.) · Fuels are toxic and flammable.  Do not get on person or clothing.  Work in well ventilated area.  Do not smoke.  Ensure equipment is well grounded. a.  Removal.  (Figure 4-10) WARNING Rubber  gloves  should  be  worn  when  handling  fueling  system  components  due  to the toxic effects of some fuel additives. (1) Remove dust cap (1) from unisex coupling (2). 4-22