Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: 4.11 REPLACE FLANGE MOUNT THREE-INCH UNISEX COUPLING.
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Back
Figure 4-7.  Inlet/Outlet Unisex Coupling Removal
Up
TM-10-4330-237-13P Filter-Separator Water Liquid Fuel for Advanced Aviation Forwarded Area Refueling System (AAFARS) Model E72FS-Z001 Manual
Next
Figure 4-8.  Flange Mount Three-Inch Unisex Coupling

TM 10-4330-237-13&P 4.11  REPLACE FLANGE MOUNT THREE-INCH UNISEX COUPLING. This task consists of: a.  Removal b.  Installation INITIAL SET-UP: Tools: Materials/Parts Required: Tool Kit, General Mechanics O-Ring (Appendix I, Item 3) (Appendix B, Section III, Item 1) Nut, self-locking (Appendix I, Item 2) Chemical and Oil Protective Gloves Cloth, Lint Free (Appendix F, Item 1) (Appendix B, Section III, Item 2) Petrolatum (Appendix F, Item 2) Pan, Drain (Appendix B, Section III, Item 2) Goggles (Appendix B, Section III, Item 2) General Safety Requirements: Equipment Condition: Liquid fuel filter-separator removed from WARNING AAFARS.  (TM 10-4930-250-13&P, para.  2.8.) · Fuels are toxic and flammable.  Do not get on person or clothing.  Do not use near open flame.  Area should be well ventilated. · Using dry cleaning solvents incorrectly can cause injury or even death. · Fuel is flammable.  Do not smoke. a.  Removal.  (Figure4-8) WARNING · Rubber gloves should be worn when handling fueling system components due to the toxic effects of some fuel additives. · Serious eye and skin injury could occur from venting of fuel when manual vent valve is opened.  Wear suitable protective clothing and eye protection. NOTE This  procedure  assumes  that  the  liquid  fuel  filter-separator  has  been  defueled. However, some fuel will remain in the diverter cavity after defueling. (1) Connect the liquid fuel filter-separator grounding cable (1) to a ground rod. (2) Depress and latch open the manual vent valve (2) to relieve any pressure from filter vessel (3). (3) Drain fuel from diverter cavity into a suitable container by removing filter vessel gravity drain plug (4). (4) Dispose of the drained fuel in accordance with local SOP. (5) Remove the six bolts (5), flat washers (6) and self-locking nuts (7) that secure the flange mount unisex coupling (8) to the filter vessel (3).  Discard the self-locking nuts. 4-18