2.2  LEAKAGE CRITERIA.
Up
TM-10-4330-237-13P Filter-Separator Water Liquid Fuel for Advanced Aviation Forwarded Area Refueling System (AAFARS) Model E72FS-Z001 Manual
Next
Section III.  OPERATION UNDER USUAL CONDITIONS

TM 10-4330-237-13&P Table 2-2.  Operator's Preventive Maintenance Checks and Services Item Interval Location PROCEDURE NOT FULLY MISSION Item to CAPABLE IF No. Check/ Service WARNING Fuel fumes are always present in the vicinity of the liquid fuel  filter-separator.    Death  or  personal  injury  may  result from  the  explosion  of  fuel  fumes  exposed  to  an  open flame  or  spark.    Do  not  permit  any  smoking,  any  open flame  or  spark  producing  equipment  within  fifty  (50)  feet (15m) of the Pumping Assembly. 1 Before Liquid fuel Inspect for physical damage that might prevent successful Physical damage will not filter-separator  operation. allow normal operation of module. 2 Before Liquid fuel Check bolts on inlet and outlet couplings.  If any bolt or nut is Any coupling is not filter-separator   loose, notify supervisor. securely tightened. 3 Before Liquid fuel Check that ground cable attachment screw and clamp are tightly Ground cable connections filter-separator  fastened.  If loose notify Unit Maintenance. are loose. ground cable assembly 4 Before Liquid fuel Remove the dust cap (1), depress continuity ball (2) on valve seat, Continuity ball does not filter- release and observe that ball pops back out.  If ball does not pop pop back in place. separator back freely, electrical continuity is lost and static discharge is unisex possible.  The coupling must be replaced.  Notify unit maintenance. couplings 5 During Liquid fuel- Drain water from sump to avoid freezing. filter separator 6 During Liquid fuel- Periodically check for leaks, especially at unisex couplings, vessel Any Class I, Class II or filter separator  end cover and sight gauge.   Class III fuel leak is found. 2-5