Alarm  switchboard  visual  displays  and  audible  outputs
Up
Fire Controlman Volume 04-Fire Control Maintenance Concepts
Next
RECOMMENDED   READING   LIST

On  the  lower  half  of  each  alarm  module  is  a  four- way   position   switch   that   allows   you   to   place   the individual  alarm  module  in  the  following  modes: NORMAL:  This  is  the  normal  operation  mode. With  the  sensor  contacts  open,  the  upper  indicator lamp  in  the  module  is  on  steady  while  the  lower  lamp is  off.  If  an  alarm  condition  occurs,  the  sensor  con- tacts  will  close;  the  upper  lamp  will  then  flash  while the  lower  lamp  remains  off  and  an  alarm  command from  the  module  actuates  atone  generator,  producing a  wailing  alarm.  If  the  sensor  loop  is  open-circuited, with  the  selector  switch  in  the  NORMAL  position,  the alarm  module  will  signal  a  supervisory  failure.  In  this case,  the  upper  lamp  will  be  off  while  the  lower  lamp will  be  steadily  on,  and  the  tone  generator  will  come on,  producing  a  pulsating  alarm. STANDBY:  This  is  the  position  for  acknowl- edging  an  alarm.  If  the  selector  switch  is  moved  from the  NORMAL  to  the  STANDBY  position  during  an alarm  condition,  both  the  upper  and  lower  indicator lamps  will  be  steadily  on  and  the  audible  alarm  will be  silenced.  When  the  alarm  condition  is  cleared  with the  selector  switch  in  the  STANDBY  position,  the lower  lamp  will  change  to  a  flashing  mode  and  the upper  lamp  will  go  out.  Also,  the  command  will  be fed  to  the  tone  generator,  producing  a  pulsating  alarm. CUTOUT:  With  the  selector  switch  in  the CUTOUT  position,  the  upper  lamp  is  out  while  the lower lamp is steadily on. In this position, power is re- moved  from  the  sensor  loop  to  facilitate  maintenance. TEST: The TEST selector switch position sim- ulates  an  alarm  condition.  The  upper  indicator  lamp flashes  while  the  lower  lamp  is  off,  producing  a  wail- ing  alarm. LIQUID-COOLING    SYSTEM MAINTENANCE  RESPONSIBILITY The  most  important  responsibility  that  you  have  as a  Fire  Controlman  that  will  extend  the  life  of  the liquid-cooling  system  components  and  increase  the reliability  of  the  cooling  system  is  how  you  perform preventive  and  corrective  maintenance  according  to the  PMS.  Properly  performed  preventive  maintenance drastically   reduces   the   amount   of   corrective   mainte- nance  necessary.  When  cooling  systems  are  neglected, they  deteriorate  very  quickly.  To  restore  the  cooling system   to   its   proper   performance,   you   may   have   to undertake   extreme   and   costly   repairs. The   PMS   responsibility   of   the   cooling   system varies  from  one  system  to  another.  On  some  systems, the  engineering  department  has  the  total  responsibility of   preventive   and   corrective   maintenance.   On   other systems,  you  will  share  the  maintenance  responsibility jointly  with  the  engineering  department.  In  these situations,  the  Fire  Controlman  will  probably  perform the  preventive  maintenance,  and  the  engineers  will perform  the  corrective  maintenance  on  major  com- ponents. When  assigned  the  responsibility  for  maintaining the  cooling  system,  you  should  perform  the  preventive maintenance   in   accordance   with   the   maintenance requirement  cards  (MRCs)  for  that  equipment  to maximize  the  operation  of  the  cooling  system. 2-26