CIRCULATING   PUMPS
Up
Fire Controlman Volume 04-Fire Control Maintenance Concepts
Next
Organic  Removal  Cartridge

through  it  will  result  in  overheating  and  seizure  of  the This   type   of   maintenance   is   normally   performed pump.  Included  in  the  corrective  maintenance  of  the by   the   ship’s   engineering   department;   you   should circulating  pump  are  repairing  any  leaks,  replacing  the provide  assistance  if  it  is  needed.  Figure  2-19  shows mechanical  seal,  and  cleaning  the  internal  parts. a   distilled-water   circulating   pump. Figure  2-19.—Distilled-water  circulating  pump. DEMINERALIZERS Demineralizes  are  used  to  maintain  the  secondary cooling  system’s  water  purity  in  an  ultrapure  state.  By maintaining   the   coolant   at   a   high   degree   of   purity, corrosion  and  scale  formation  is  minimized  on  the radar  unit. Corrosion   or   scale   on   high-heat-density   compo- nents,  such  as  waveguide  dummy  loads  and  klystrons, results  in  the  formation  of  a  thermal  barrier.  The  ther- mal  barrier  reduces  the  effectiveness  of  heat  transfer at   normal   operating   temperatures,   which,   in   turn, leads  to  premature  failure  of  the  components. The   demineralizer   is   connected   between   the   sec- ondary  cooling  system  supply  and  return  lines  to  cir- culate  water  through  it.  The  demineralizer  is  sized  so that  5  percent  of  the  cooling  system  volume  passes through  the  demineralizer  every  hour.  The  coolant  is purified   by   organic   compound   adsorption   (if   re- quired),  oxygen  removal,  ion  exchange  processes,  and submicron    filtration. Figure  2-20  shows  a  typical  three-cartridge  demin- eralizer.  Some  demineralizers  use  only  two  cartridges, with  one  of  the  cartridges  being  a  combination  car- tridge   that   provides   organic   compound   adsorption,   if it  is  required. 2-20

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing