Figure 3-8.-Rear view of a switchboard showing bus bars and disconnect links
Up
Electronics Technician Volume 08-Support Systems
Next
THREE-PHASE GENERATORS

Figure  3-9.-Disconnect  links. The switchboards shown in figures 3-5,3-6, and 3-7 are representative of the found on most gas-turbine powered  ships  today.  These  switchboards  use  sheet steel  panels  or  enclosures  from  which  only  the  meters and  the  operating  handles  protrude  to  the  front. Distribution of the generated power begins with the switchboard.  These  switchboards  can  be  connected together  through  bus  tie  circuit  breakers  to  form  a continuous loop. This allows any two of the three gas turbine  generator  sets  (GTGS’s)  to  supply  the  demand for  power,  while  the  third  can  be  set  up  to  start automatically  in  the  event  of  a  power  loss.  (See  figure 3-8.) Each  of  the  switchboard  units  of  a  group  are connected  together  through  disconnect  links  (fig.  3-9). By  removing  the  links  between  any  two  of  the switchboards, repairs or replacement of parts may be accomplished  without  interfering  with  the  operation  of the other units. GROUND DETECTOR CIRCUITS A set of three ground detector lamps (fig. 3-10) is connected through transformers to the main bus of each ship’s  service  switchgear  group.  It  provides  you  with  a means  to  check  for  grounds  on  any  phase  of  the three-phase  system. To check for a ground, turn switch S on and observe the brilliancy of the three lights. If the lights are equally bright, all lights are receiving the same voltage, and no ground exists. If lamp A is dark and lamps B and C are bright, phase A is grounded. In this case, the primary of the transformer in phase A is shunted to ground, and lamp A receives no voltage. Similarly, if lamp B is dark and lamps A and C are bright a ground exists on phase B. If lamp C is dark and lamps A and B are bright, a ground exists on phase C. Figure 3-10.-An ac ground detector lamp circuit. 3-7