Electronics Technician Volume 08-Support Systems
Next
TYPE I COOLING SYSTEM

Figure 1-8.—Type III liquid cooling system. taken from the firemain through a duplex strainer and a flow regulator (orifice plate) to and through the heat exchanger.  It  is  then  discharged  overboard.  The connection  to  the  firemain  is  permanent. The ship’s fire pump, not shown in figure 1-7, is used to pump seawater into the firemain. The fire pump is similar in design to the previously mentioned seawater circulating pump, except it has a much larger capacity. Another means of getting seawater as a primary coolant is by an emergency connection (figs. 1-6 and 1-7). This method is used if the normal seawater supply is lost. The connection is usually by means of a 1-inch fire  hose.  The  emergency  supply  comes  from  an alternate portion of the ship’s firemain or a portable pump  rigged  by  the  ship’s  damage  control  party.  The portable emergency hose is normally stored in the liquid coolant  machinery  room. Note:  Seawater  systems  are  referred  to  as open-looped or one-pass because the seawater flows through the system only once. In figures 1-7 and 1-8, chilled water is taken from the  supply  main  of  the  air-conditioning,  chilled-water systems. The chilled water is used as a backup source of cooling water for the primary cooling system shown in figure 1-7, and as a normal and backup source in the system shown in figure 1-8. The chilled water flows through the tubes of the heat exchanger (chilled water to distilled water), a flow regulator, and back to the chilled-water system. A temperature regulating valve at the inlet of the heat exchanger regulates the flow of chilled  water  through  the  heat  exchanger  to  maintain  the required  water  temperature  in  the  secondary  system (distilled   water). The   ship’s   air-conditioning, chilled-water circulating pump is used to pump the chilled   water   through   the   heat   exchanger.   The chilled- water system is a closed-loop water system because the water is recirculated. It must be kept tight and free from leaks to assure satisfactory operation. SECONDARY  COOLING  SYSTEM The  secondary  cooling  system  is  designed  to transfer  heat  from  the  electronic  equipment  being cooled to the primary cooling system. This system is usually comprised of a distilled- water circulating pump, a  compression  or  gravity-feed  expansion  tank,  the 1-6

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing