Click Here to
Order this information in Print

Click Here to
Order this information on CD-ROM

Click Here to
Download this information in PDF Format

 

Click here to make tpub.com your Home Page

Page Title: Figure 5-12.—The LMS-11 PU Display mode.
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books

   
Back
Figure 5-11.—The LMS-11 Net Display in PU History Mode.
Up
Electronics Technician Volume 03-Communications Systems
Next
PU  Display

Figure 5-12.—The LMS-11 PU Display mode. Values  between  1  and  100  could  be  due  to  noise  or PHASE   ERR   M.   —This  is  the  mean,  or  average, weak   equipment   or   an   equipment   malfunction. BER.  —This  is  the  bit  error  rate  measured  as  the number  of  bit  errors  per  1,000.  Bit  errors  increase  as the   signal-to-noise   ratio   decreases.   A   bit   error   rate that  exceeds  a  theoretical  value  for  a  given  SNR  is indicated   by   displaying   both   the   BER   and   SNR   in yellow. REL  605.  —This  column  indicates  the  relative power  of  the  605-Hz  tone  with  respect  to  the  average power  of  the  15  data  tones,  measured  in  dB.  It  should be  +6  dB. VAR  DATA.  —This  is  the  variation  of  power  in the  data  tones  in  dB.  The  relative  power  of  each  of the  data  tones,  with  respect  to  the  average  power  of the  data  tones,  is  determined.  The  variation  is  the difference   between   the   maximum   and   the   minimum. Under   ideal   conditions,   the   variation   is   zero.   The TADIL  A  specification  for  maximum  variation  is  1.5 dB. phase   error   of   the   data   tones.   The   intelligence-is stored in the data tones by use of the phase differences that  are  odd  multiples  of  45  degrees.  If  the  phase difference  of  a  data  frame  is  50  degrees  when  the expected  difference  is  45  degrees,  the  error  would  be 5  degrees.  The  phase  errors  for  each  tone  are  added up,  and  after  the  specified  number  of  cycles,  the  sum for  each  tone  is  divided  by  the  number  of  frames  to obtain  the  mean  phase  error  for  each  tone.  The  mean phase   error   for   all   15   tones   is   then   summed   and divided  by  15  to  obtain  the  value  displayed. PHASE  ERROR  SD.  —This  is  the  standard deviation  of  the  phase  error  in  all  15  tones. RFE/DS.  —This  is  the  radio  frequency  error,  or Doppler  shift,  measured  in  Hertz.  If  the  Doppler correction   was   enabled   during   the   LMS-11 initialization,   the   value   is   color-coded   green.   If   the Doppler  correction  is  turned  off,  this  value  is  color- coded  cyan. NCT.  —This  is  the  net  cycle  time,  as  measured from  phase  reference  frame  to-phase  reference  frame, 5-15

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing