Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: DESCRIPTION
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Back
INDIRECT    VIEW    DISPLAY    SELF    TEST    FAILURE
Up
TM-11-6625-3081-23-5 Electronic Equipment Test Facility TADS/PNVS Augmentation Equipment Manual
Next
SEGMENTS    1    THRU    46    -    ERROR    MESSAGES

TM  11-6625-3081-23 7-15. INDIRECT   VIEW   DISPLAY   (IVD)   2A1A3   WITH   OSA 7-15 INPUT   CODE:   IVDST a . DESCRIPTION This module tests the ability of the indirect view display (IVD) 2A1A3 to produce  correct  outputs  in  response  to  function  commands. An error detected during any of the following checks will display a prompt at the completion of the test. The  optical  signal  analyzer  (OSA)  chassis  to  shield  continuity  is  checked  for 10 ohms or less. The  OSA  shutter  interlock  operation  is  verified  by  checking  the shutter status with the OSA door open (shutter closed). The operator closes the OSA door,    the  shutter  is  programmed  open,  and  shutter status checked. The  internal  and  external  relays  1 through 4, phase A, B, and C contacts are checked for a closed condition. The operator opens the OSA door and the OSA shutter is checked for a closed status. The  internal  and  external  relays  1 through 4, phase A, B, and C contacts are checked for an open status. The  operator  applies  pressure  to  OSA  door  interlock  switch  S1  while  OSA  door interlock switch S2 is checked for a shorted condition. The  operator  then  releases S1 and applies pressure to S2 while S1 is checked for a shorted condition. The operator then releases S2 and closes the OSA door. The OSA door status is checked. The IVD is then programmed to produce a vertical output pulse and a horizontal output pulse, which are checked for period and amplitude. b . REPLACEMENT     PROCEDURE     REFERENCE The  following  list  provides  a  cross  reference  of  replacement  items  to replacement  procedures. The item column identifies the item to be replaced by reference  designation  and  part  number. The  reference  column  identifies  the procedural paragraph used to perform the replacement action. The VDT screen will display  the  proper  sequence  of  repair/replace  actions. Item (Ref Des/Part No.) Reference (Para  No.) 2A1A3/13078701 5-25 7-65

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing