SEGMENT 1
Up
TM-11-6625-3081-23-5 Electronic Equipment Test Facility TADS/PNVS Augmentation Equipment Manual
Next
SEGMENT   2

TM  11-6625-3081-23 7-13.   FILTER   WHEEL/MOTOR   ASSEMBLY   (VARIABLE   FILTER)   2A1A2A10 7-13 INPUT   CODE: DCVARF   (cont) 2.   CORRECTIVE   ACTION   -   SEGMENT   1    (cont) (e) Remove Stepper Motor No. 3 2A2A7A6A3. Check contacts of mating connectors  and  repair  if  required. Install  replacement  2A2A7A6A3  and perform DCVARF test. If DCVARF test passes, no further action required. If this segment displayed again, proceed to (f). If another segment  displayed,  proceed  to  that  segment  and  continue troubleshooting. (f) Remove Cable Assembly 2A1A2A1OA2W53. Check contacts of mating connectors  and  repair  if  required. Install  replacement  2A1A2A1OA2W53 and perform DCVARF test. If DCVARF test passes, no further action required. If this segment displayed again, proceed to (g). If another segment  displayed,  proceed  to  that  segment  and  continue troubleshooting. (g) Check the following cable assemblies and repair as required: W28 W29 2A1W23 2A1A2W40 2A1A2A1OW46 2A2W8 2A2W9 If any cable was repaired, perform DCVARF test. If DCVARF test passes, no  further  action  required. If DCVARF test fails and CALCST, PLLBUS, MTRXSW,  ADST,  DIGITST,  FPSST,  and  PPSST  tests  have  been  performed, repair is beyond this level of maintenance. Next higher level of maintenance  required. If no cables were repaired and CALCST, PLLBUS, MTRXSW, ADST, DIGITST, FPSST, and PPSST tests have been performed, repair is beyond this level of maintenance. Next  higher  level  of  maintenance  required. If  another  segment  displayed,  proceed  to  that  segment  and  continue troubleshooting. 7-60

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing