Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: ELECTRONICS TROUBLESHOOTING FLOW CHART DESCRIPTION (cont)
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Back
TROUBLESHOOTING   METHODOLOGY   (cont)
Up
TM-11-6625-3081-23-5 Electronic Equipment Test Facility TADS/PNVS Augmentation Equipment Manual
Next
ELECTRONICS  TROUBLESHOOTING  FLOW  CHART  DESCRIPTION  (cont)

TM  11-6625-3081-23 7-2.   TROUBLESHOOTING   METHODOLOGY   (cont) 7 - 2 ELECTRONICS  TROUBLESHOOTING  FLOW  CHART  DESCRIPTION  (cont) Symbol 6 7 8 9 10 Action RUN VSGST   - rerun test If VSGST test passes,    then Pulse Generator CCA 2A2A7A6A9 was bad. No further  action  required. If VSGST test fails and its a different fault segment, then Pulse Generator CCA 2A2A7A6A9 was faulty but another fault exists. Operator must then find correct  fault  segment  and  continue  troubleshooting. If VSGST test fails and its the same fault segment, then Pulse Generator CCA  2A2A7A6A9  was  not  faulty  and  troubleshooting  in  this  leg  continues. PERFORM  THIRD  MAINTENANCE  ACTION   -  Refer  to  REPLACEMENT  PROCEDURE  REFERENCE paragraph  and  determine  procedural  paragraph  number  to  replace  2A2A6XX/ HP69331B. Replace  Digital  Output  CCA  (Slot  406)  2A2A6XX. RUN VSGST   - rerun test. If VSGST test passes,    then Digital Output CCA 2A2A6XX was bad. No further action  required. If VSGST test fails and its a different fault segment, then Digital output CCA 2A2A6XX was faulty but another fault exists. Operator must then find correct  fault  segment  and  continue  troubleshooting. If VSGST test fails and its the same fault segment, then Digital Output CCA 2A2A6XX  was  not  faulty  and  troubleshooting  in  this  leg  continues. PERFORM  FOURTH  MAINTENANCE  ACTION   -  Refer  to  REPLACEMENT  PROCEDURE REFERENCE  paragraph  and  determine  procedural  paragraph  number  to  replace 2A2A7A6A7/13082714. Replace  Bus  Multiplexer  CCA  2A2A7A6A7. Run VSGST   - rerun test. If VSGST test passes,    then Bus Multiplexer CCA 2A2A7A6A7 was bad. No further  action  required, If VSGST test fails and its a different fault segment, then Bus Multiplexer CCA 2A2A7A6A7 was faulty but another fault exists. Operator must then find correct  fault  segment  and  continue  troubleshooting. If VSGST test fails and its the same fault segment, then Bus Multiplexer CCA  2A2A7A6A7  was  not  faulty  and  troubleshooting  in  this  leg  continues. 7-7

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing