TM-11-6625-3081-23-5 Electronic Equipment Test Facility TADS/PNVS Augmentation Equipment Manual
Next
TROUBLESHOOTING   METHODOLOGY   (cont)

TM  11-6625-3081-23 7-2.   TROUBLESHOOTING   METHODOLOGY   (cont) 7 - 2 Symbol 1 2 3 4 5 ELECTRONICS  TROUBLESHOOTING  FLOW  CHART  DESCRIPTION Action RUN VSGST -   refer to chapter  2 for  self-test  instructions. If VSGST test passes,    no further action required. If VSGST test fails, then the correct fault segment must be determined. If segment 1 is not displayed, then the operator must find the correct segment  before  continuing. For this example,    segment 1 is displayed. This is the VDT display of the repair message for segment 1. NOTE Prior  to  performing  replace  actions,  check test  tools  for  faults  (connector  seating, continuity,  physical  damage,  etc.)  and rerun test module. PERFORM  FIRST  MAINTENANCE  ACTION   -  refer  to  REPLACEMENT  PROCEDURE  REFERENCE paragraph. Under  heading   “Item (Ref Des/Part No.)” find 2A2A7A6A8/ 13083050-19. On this line under the heading “Reference (Para No.)” is paragraph number 2-51. Refer to chapter 2, paragraph 2-51 and replace Pulse Generator CCA #1 2A2A7A6A8. RUN VSGST   - rerun test. If VSGST test passes,    then Pulse Generator CCA 2A2A7A6A8 was bad. No further  action  required. If VSGST test fails and its a different fault segment, then Pulse Generator CCA 2A2A7A6A8 was faulty but another fault exists. Operator must then find correct  fault  segment  and  continue  troubleshooting. If VSGST test fails and its the same fault segment, then Pulse Generator CCA 2A2A7A6A8 was not faulty and troubleshooting in this leg continues. PERFORM  SECOND  MAINTENANCE  ACTION   -  Refer  to  REPLACEMENT  PROCEDURE REFERENCE  paragraph  and  determine  procedural  paragraph  number  to  replace 2A2A7A6A9/13081467-19. Replace  Pulse  Generator  CCA  #2  2A2A7A6A9. 7-5