INSTALLATION

TM  11-6625-3081-23 5-6. BASE ASSEMBLY REPAIR (cont) 5-6 (36) Install two transport retainer  brackets  (9)  with six screws (7) and washers (8). Torque screws (7) to 50 ft-lb. (37) Install two studs (5) into base assembly (6). (38) Install two protective cups (4) with four screws (1), lockwashers (2), and washers (3). (39) Refer to 1 above and install protective  skirts. (40) Refer to paragraph 5-7 and adjust base assembly. END OF TASK d. To replace isolator number 4, proceed as follows: REMOVAL (1) Refer to 2C above and perform steps 1 thru 9. (2) On isolator (1), disconnect blue tube (2) from fitting (3). (3) Remove piston plate (4) from isolator  (1). (4) Mark a line around bottom of isolator  (1).  Replacement isolator must be installed in same position. (5) Remove two bolts (5), lock- washers (6), and isolator (1). (6) Remove fitting (3) from isolator and clean teflon tape residue from threads. 5-28

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing