TM  11-6625-3081-23 5-6. BASE ASSEMBLY REPAIR (cont) 5-6 (10) (11) (12) (13) (14) (15) (16) (17) On isolator (16), tag and disconnect  two  blue  tubes (17) from tee fitting (18) and natural tube (19) from opposite fitting (20). Tag  and  disconnect  blue  tube (21) from fitting (22) on isolator (16). Remove piston plate (23) from isolator (16). Remove tubing clamps as necessary. Mark a line around bottom of isolator  (16).  Replacement isolator must be installed in same position. Remove two bolts (24), lock- washers  (25),  and  isolator (16). Remove four screws (26) and valve assembly (27) from isolator  (16). Remove  fitting  (22)  from defective  isolator  (16)  and clean teflon tape residue from threads. 5-24