TM  11-6625-3081-23 5-6. BASE ASSEMBLY REPAIR (cont) 5-6 (4) Remove piston plate (8) from isolator  (1). (5) Remove tubing clamps as necessary. (6) Mark a line around bottom of isolator  (l).  Replacement isolator must be installed in same position. (7) Remove two bolts (9), lock- washers  (10),  and  isolator (1). (8) Remove four screws (11) and valve assembly (12) from isolator  (1). (9) Remove fitting (7) from defective  isolator  and  clean teflon tape residue from threads. INSTALLATION (10) Wrap teflon tape around threads of fitting (7). (11) Install fitting (7) into replacement isolator (1). 5-19