Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: Radiometer Assembly Characteristics
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Back
Inner  Module  2A1A2
Up
TM-11-6625-3081-23-1 Electronic Equipment Test Facility TADS/PNVS Augmentation Equipment Manual
Next
Inner Module 2A1A2

TM  11-6625-3081-23 1-12. DESCRIPTION OF DAYSIDE TEST BENCH 2A1 (cont) 1-12 (3) The radiometer assembly 2A1A2A3 is located in the top center section of the test bench behind the beam sampler 2A1A2A13 and laser mount. The assembly consists of a detector head, a radiometer,    and  a  component  assembly  (power  supply  and  filtering network). The  radiometer  assembly  mounts  to  a  support  assembly  that  is  secured  to  the inner  module. The rear panel of the detector head contains a toggle switch, two rotary switches,   a  coaxial  connector,  and  a  rectangular  connector. These switches  and  the  coaxial  connector  are  used  for  testing  the  radiometer  assembly. Coaxial  cable  assembly  2A1A2W22  connects  between  the  detector  head  and  cable  entry panel 2A1A2A17 for system output. Cable  assembly  2A1A2W40  connects  to  the  rectangular connector  and  inputs  power,  transmits  feedback  signals,  and  provides  a  signal  measure- ment source. The purpose of the radiometer assembly is to make laser power tests, detect missed laser pulses,   and  determine  pulse  width  and  energy  stability  between pulses. Radiometer  Assembly  Characteristics: Maximum Peak Current: 100 mA Maximum Average Current: 1.0 mA Effective  Active  Area  (Diffuser): 2.58 in2; 16.6 cm2 Pulse Rise Time (Scope viewing): 8 ns across 50 ohms Pulse  Viewing  Resistors: 50 ohms, 500 ohms, 5000 ohms, OPEN Aperture  Ratios: 1, 1/3, 1/10, 1/30, 1/100, 1/300, 1/1000, and 1/3000 Physical  Dimensions: Length 6.50 in Width 5.25 in Height 7.50  in Weight 8 lb (4) The dayside sensor mount assembly 2A1A2A4 is a heavy, cast aluminum mount that supports and positions the TADS day sensor assembly UUT for testing. It is mounted to the front side of the dayside test bench and consists of sensor mount, laser  safety  shield,  laser  interface  carriage,    end  plate,  laser  interlock  rod,  four cable assemblies, an actuator switch, and a UUT dayside mounting adapter. (a) The sensor mount contains the mount bracket, sensor mount (UUT locking) handle, and cable assembly. The handle is manually positioned to lock or to unlock the UUT to the mount bracket. The  handle  in  the  forward  position  (unlock-towards dayside test bench) retracts four locking cams. The handle in the aft position reverses the position of the cams and locks the UUT to the mount bracket. The cable assembly contains two optical switch assemblies, A1 and A2, that sense the lock or unlock position. (b) The laser safety shield, laser interface carriage, laser carriage handle, laser interlock rod, and end plate make up the holding assembly for the UUTs, laser transceiver and laser tracker receiver. 1-43

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing