MOVEMENT OF EQUIPMENT.
Up
TM-55-4920-231-14 Tester Pitot and Static Systems Part Number REIC 340000 Manual
Next
Chapter 3. OPERATOR'S AND ORGANIZATIONAL MAINTENANCE INSTRUCTIONS

TM 55-4920-231-14
Section IV. OPERATION UNDER UNUSUAL CONDITIONS
and 19) turned to open valves before starting
46. GENERAL.
tests.
This section contains special operating instruc-
tions which are necessary for the proper func-
48. OTHER UNUSUAL CONDITIONS.
tioning of the tester under unusual conditions.
CAUTION
47. EXTREMES OF HEAT AND COLD.
Contamination in the pneumatic or lu-
bricating systems will- damage the in-
The tester is designed to operate in tempera-
tures from 40°F. to 160°F (40°C. to 71°C.).
struments controls and the pump.
When operating in normal or extreme high tem-
a. When operating the tester in extreme con-
peratures to 160°F, use the high temperature oil
ditions of snow, ice, rain, mud, dust, salt air, or
in the reservoir for lubricating the pump. For
similar conditions, do everything possible to pre-
extreme low temperature operating range (from
vent foreign material from entering the pneu-
+32°F. to -40°F), use the low temperature oil
matic or lubricating systems.
and operate the pump for at least 5 minutes with
b. After operation in extreme conditions, thor-
both selector valve knobs (10 and 20, figure 7)
oughly clean and dry the tester and accessories.
in the OFF position and the knobs (11, 12, 17,