Page Title: Ohms Measurement Tests
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Back
Beta Measurement Test (Out-of-Circuit)
Up
TM-11-6625-539-14-4 Test Set Transistor TS-1836 D/U Manual
Next
Transconductance Test (FET In-Circuit)

TM 11-6625-539-14-4
7-19. Ohms Measurement Tests
b. Test Connections and Conditions. As indi-
cated below.
a. Test Equipment and Materials.
c. Procedure.
(1) Resistor, Decade ZM-16/U.
(2) Multimeter AN/USM-223.
('ontrol settings
Step
Performance
Test procedures
No.
Test
Equipment
equipment
under test
1
N/A
POLARITY  switch:
a. Meter deflects to near full
a. Check meter deflection.
scale.
E-B.
FUNCTION switch:
b. Meter shows exact full-scale
b. Adjust meter for full-scale
deflection.
OHMS:
deflection.
c. Meter  can  be  adjusted  to
R A N G E switch: X
c. Short across E­B jacks and
0.1.
check zero deflection of me-
zero.
ter.
ICES
ZERO/OHMS
d. Opne E­B contacts result in
d. Repeat a through c above un-
exact full-scale deflection.
ADJUST controls.
til full scale deflection and
When shorted, meter reads
METER ZERO con-
zero deflection are achieved.
exact zero.
trol.
Meter must read 300 ohms ±5
C o n n e c t decade box to
E-B
Same.
2
Set decade box to 30
percent on OHMS scale.
jacks.
ohms.
Meter must read 1k ohms ±5
C o n n e c t decade box to
E-B
Same.
3
Set decade box to 100
percent on OHMS scale.
jacks.
ohms.
Meter must read 3k ohms ±5
C o n n e c t decade box to
E-B
4
Set decade box to 300
Same.
percent on OHMS scale.
jacks.
ohms.
Meter must read 300, 1k, and 3k
Repeat steps 2 through 4
con-
5
Set decade box to 30,
Same except PO-
ohms on OHMS scale with
LARITY switch:
necting decade box to
C­B
100, and 300 ohms
successive tests. All readings
C-B.
jacks.
successively,
must be ±5 percent of decade
box setting.
Meter must read 300, 1k, and 3k
Repeat steps 2 through 4 con-
6
Set decade box to 30,
Same except PO-
ohms on OHMS scale with
necting decade box to E­C
100, and 300 ohms
LARITY switch:
successive tests. All readings
jacks.
successively.
E-C.
must be within ±5 percent of
decade box setting.
Open E-B terminals cause full-
Repeat
step 1 to adjust full-
POLARITY  switch:
`7
N/A
scale deflection. When E­B
C-B.
scale
deflection with C­B
terminals are shorted, meter
R A N G E switch: X
open
and zero deflection
is exactly zeroed.
1.0.
when
shorted.
F U N C T I O N switch:
OHMS.
Meter must read 300, 1k, and 3k
Repeat steps 2 through 6 to
Same.
8
S e t decade box to
check out resistive loading of
ohms on OHMS scale with
300, 1K, and 3K
successive tests. All readings
C-B at each of the selected
ohms successively.
must be within ±5 percent of
resistances.
decade box settings.
Open. terminals cause full scale
Repeat
step 1 to adjust full
POLARITY  switch:
N/A
9
deflection. When E-B termi-
E-C.
scale
deflection with E­C
nals are shorted, meter is ex-
FUNCTION switch:
open
and zero deflection
actly zeroed.
when
shorted.
OHMS
R A N G E switch: X
10.
Meter must read 300 and 1k on
Repeat steps 2 through 6 to
Same.
10
Set decade 3K and
the OHMS scale with succes-
check out resistive loading of
10K ohms succes-
s i v e tests. Both readings
E-C at each of the selected
sively.
must be within ±5 percent of
resistances.
decade box setting.
7-12