![]() ![]() TM 11-6625-539-14-3
b. Circuit Resistance Measurement:
(2) In circuit
G-S load
D-S load
Accuracy
GM
(1) Emitter-to-base.
100 ohms . . ..4.000 ohms ±10 percent
O to 2,50O microohms.
Range
Accuracy
Maximum power output
e. Diodes and Rectifiers. Diodes and rectifiers are
0 to 5,000 ohms . . . . . . . . . . .±5 percent . . . . . . . . . . . 0.25 microwatt.
measured in-circuit for shorts and opens, which are
(2) Collector-to-base.
detected with loads of 20 ohms or greater across the
Range
Accuracy
Maximum power output
device terminals.
f . IR a t VR = 6 V o l t s .
0 to 5,000 ohms . . . . . . . . . . ±5 percent. . . . . . . . . .. 0.25 microwatt.
Range
I.R
Accuracy
(3) Collector-to-emitter.
O to 100 microampere . . . . ±3 percent of full-scale reading.
xl
Range
Accuracy
Maximum power output
X10 0 to 1 milliampere . . . . . . . .±3 percent of full-scale reading.
0 to 5,000 ohms . . . . . . . . . . .±5 percent.. . . . . . . . .. 0.25 microwatt.
g. Diodes, Reverse-to-Forward Ratio.
Out of circuit.
c . IC B V C B = 6 Volts; I E= 0 .
Accuracy
Ratio
Range
I cbo
Accuracy
1:10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . *5 percent.
x1
O to 100 microampere . . . . . ±3 percent of full-scale reading.
1-6. Items Comprising an Operable Equip-
X10 0 to 1 milliampere... . . . . . . ±3 percent of full-scale reading
ment
in circuit.
The TS-1836C/U is a self-contained test set. The test set
d. Field Effect Transistors.
measures approximately 7 inches wide, 6½ inches deep,
(1) Out of circuit.
and 8½ inches high. The test set weighs approximately
GM
Accuracy
3½ pounds.
0 to 2,500 microohms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±5 percent.