c.  The type BNC 50-ohm termination adapter supplied has a VSWR of less than
1.2:1 up to 600MHz. The adapter has a 5 watt max. power rating.
d.  The high impedance probe tip supplied allows for direct high impedance
measurements up to 250MHz. However, a short wire should be substituted for the
ground lead when using above 100MHz to minimize the effects of ground lead in-
duction.
e.  T h e main controls required to operate the voltmeter are on the front panel.
Several minor controls are on the rear panel.
TECHNICAL CHARACTERISTICS
Voltage range . . . . . . . . . . . . . . . . . . . . . 100µV to 3V, 8 ranges; 0.001V to 3V full scale
dBm range . . . . . . . . . . . . . . . . . . . . . . . . . -60 to + 23, 8 ranges in 10dB steps per range
Frequency range . . . . . . . . . . . . . . . . . . . 20KHz to600MHz
Frequency response . . . . . . . . . . . . . . . . True RMS up to 30mV, peak reading above 1V
Wide band accuracy . . . . . . . . . . . . . . . . ( s e e Fig. 1-1)
0.003V Full Scale to
Frequency
0.001V Full Scale Range
3V Full Scale Ranges
±15% of full scale
±10% of full scale
20KHz to 100MHz
±10% of full scale
100MHz to 400MHz
± 5 % of full scale
±10% of full scale
±15% of full scale
400MHZ to 600MHZ
INPUT IMPEDANCE . . . . . . . . . . . . . . . . . . .
Approx. 2.2 pf and 200K
V.S.W.R. . . . . . . . . . . . . . . . . . . . . . . . . . .
Less than 1.2:1 at 600MHz
CREST FACTOR . . . . . . . . . . . . . . . . . . . . . .
4 5 0 to 1.4 (function of input voltages)
MAXIMUM INPUTS . . . . . . . . . . . . . . . . . . . .
RF: 42V P-P or 15V RMS; DC: 400V
DC OUTPUT . . . . . . . . . . . . . . . . . . . . . . . . .
1.0V, 1mA max. at full scale, linear. Impedance
load of 2K , ±1% required
RISE TIME . . . . . . . . . . . . . . . . . . . . . . . . .
1 sec. on the 0.001V full scale range, de-
c r e a s i n g to 100 millisec. about the 0.01V full
scale range
INDICATOR . . . . . . . . . . . . . . . . . . . . . . . . .
Precision 5.5" taut band meter movement,
m i r r o r - b a c k e d dial and knife edge pointer. Ex-
panded linear dial scales except dBm.
LINE VOLTAGE & POWER . . . . . . . . . . . . . .
115V or 230V AC +20%, 45-1000Hz; less than 12W
DIMENSIONS&WEIGHT . . . . . . . . . . . . . . .
9" H x 6.5"W x 11.25" D. Weight approx. 12 lbs.
for 0 d B m  l e v e l .