![]() ![]() (2) Plug the black test lead into the OHMS-
DC±AC jack.
(3) Plug the red test lead into the O H M S
jack.
(4) Set the range switch to the desired posi-
tion and touch the two test lead prods together.
(5) Turn the OHMS ZERO ADJ. knob until
meter pointer appears directly over the 0 on the
right side of the OHMS scale.
(6) Separate the test lead prods.
b. Measuring Resistance.
(1) Repeat procedures described in a (l), (2),
and (3) above.
(2) If the approximate resistance of the cir-
cuit under test is known, turn the range switch to
the appropriate resistance range and zero adjust
the meter (a (4), (5), and (6) above).
(3) Connect the test prods across the resist-
ance to be measured.
(4) Read the meter indication on the OHMS
scale.
(5) If the resistance to be measured is un-
known, proceed as follows:
(a) Set the range switch to RX10000.
(b) Connect the test prods across the un-
known resistance.
(c) Turn the range switch counterclock-
wise, one range at a time, until the meter pointer
stops close to midscale.
(6) Zero adjust the meter (a (4), (5), and (6)
2-11
|
|