Click here to make tpub.com your Home Page

Page Title: Section II. DESCRIPTION AND DATA
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Back
Chapter 1. INTRODUCTION
Up
TM-11-6625-316-12 Test Sets Electron Tube TV-2/U TV-2A/U and TV-2B/U Manual
Next
Components of Test Set, Electron Tube TV-2(*)/U

Materiel Support Agency, ATTN: SIGMS-PA2d, Fort Monmouth,
N.J.
Section II. DESCRIPTION AND DATA
3. Purpose and Use
Test Set, Electron Tube TV­2(*)/U (fig. 1) is a portable tube
t e s t e r of the dynamic mutual conductance type. It is used to test
and to measure performance capabilities and to determine rejec-
t i o n limit for electron tubes used in receivers, low-powered trans-
mitters, and other electronic equipment. The following tests can
b e made with the tube tester.
a. S h o r t t e s t .
b. I n t e r e l e m e n t l e a k a g e t e s t .
c. F i l a m e n t c o n t i n u i t y t e s t .
d. Dynamic mutual conductance test for amplifier tubes.
e. Gas test for amplifier tubes.
f. Emission test for vacuum rectifier tubes.
g. Test of gas rectifier tubes.
h. Test of voltage regulator tubes.
i. Plate current tests for triodes.
j. T e s t o f t h y r a t r o n t u b e s .
k. Electron-ray indicator test for electronic indicator tubes.
l. Ballast
tube
test.
4. Technical Characteristics
a. Power supply:
Input voltage ________________ 103.5 to 126.5 volts ac.
Frequency------------------------ 50 to 1,000 cps, single-phase.
Power consumption -------------70 watts (no tube under test).
Temperature range ----------- Satisfactory operation from -4° F. to 125° F.
b. Meters:
FILAMENT VOLTS meter:
Type------------------------------ Dc voltmeter movement.
Frequency range ----------- 50 to 1,000 cps.
Ac voltage ranges -------------- 0 to 2.5 volts, 0 to 10 volts, 0 to 40 volts, and
0 to 120 volts. Redlines at 0.625, 6.3, 12.6,
and 117 on appropriate scale.
Accuracy -------------------------- ±5 percent error at full scale.
GRID BIAS VOLTS meter:
Type ---------------------------------Dc voltmeter.
Sensitivity ---------------- 1,000 ohms per volt.
Dc voltage ranges ---------- 0 to 5 volts, 0 to 10 volts, and 0 to 50 volts.
Accuracy-------------------------- ±2 percent error at full scale.

Privacy Statement - Press Release - Copyright Information. - Contact Us