TROUBLESHOOTING-continued
Up
TM-11-6625-291-14 Output Meters TS-585A/U TS-585B/U TS-585C/U (NSN6625-00-244-0501) TS-585D/U (NSN6625-00-684-5438) Manual
Next
CHAPTER 4. ORGANIZATIONAL MAINTENANCE

TM 11-6625-291-14/TO 33A1-7-23-1
Section Ill MAINTENANCE PROCEDURES
Para
Subject
Page
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
Touchup Painting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6
3-3. OVERVIEW.
This section provides maintenance procedures for the output meter at the operator maintenance
level.
The maintenance procedures for the output meter are organized into the following groups:
Inspection
Cleaning
Touchup Painting
3-4. INSPECTION.
The only inspection procedures at the operator maintenance level are the PMCS. The PMCS must be
performed at the intervals listed. See chapter 2, section ll for the PMCS procedures.
3-5. CLEANING.
Clean the output meter panel with a lint-free cloth. It maybe necessary to clean meter glass
using soap and a dampened cloth. The metal parts of output meter can be cleaned using
trichlorotriflouroethane.
Adequate ventilation should be provided while using trichlorotrifluoroethane. Prolonged
breathing of vapor should be avoided. The solvent should not be used near heat or open
frame; the products of decomposition are toxic and irritating. Since trichlorotrifluoroethane
dissolves natural oils, prolonged contact with skin should be avoided. When necessary, use
gloves which the solvent cannot penetrate. If the solvent is taken internally, consult a physi-
cian immediately.
CAUTION
Do not clean meter glass with trichlorotrifluoroethane. This can damage the output
meter.
3-6. TOUCHUP PAINTING.
Remove rust and corrosion from metal surfaces by lightly sanding surfaces with fine sandpaper. Brush
two thin coats of proper paint on bare metal. See TM43-0139 for cleaning and refinishing instructions.
3-5/(3-6 blank)