Click here to make tpub.com your Home Page

Page Title: Section II. CONTROLS AND INDICATORS
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Back
Chater 2. INSTALLATION AND OPERATING INSTRUCTIONS
Up
TM-11-6625-274-12 Test Sets Electron Tube TV-7/U TV-7A/U TV-7B/U and TV-7D/U Manual
Next
Pushbutton Switches.

(6) Open the inner fiberboard carton and
1.2 cubic feet, and the weight is
remove the contents.
pounds.
b.
Removing
Contents.
Checking
Unpacked
Equipment
Check
the
equipment
against
the
packing
( 1 ) Cut and fold back the metal straps
list.
When
no
packing
list
accompanies
the
(when
used).
equipment, use the table of components (par.
( 2 ) Remove
the
nails
from
the
wooden
5)
as
a
general
check.
If
the
equipment
is
cover
and
one
side
of
the
wooden
damaged, refer to paragraph 2. After a test set
packing
case
with
a
nailpuller.
Re-
is
removed
from
its
fiberboard
container,
re-
move the cover and the side. Do not
lease the fasteners, open the cover, and proceed
attempt to pry off the cover or the
as follows:
side; prying may damage the equip-
a. Check
to
see
that
the
adapters
ment.
are held firmly to the cover.
b. Check all controls for ease of rotation.
( 3 ) Remove the envelope that contains the
Tighten loose knobs.
technical manuals.
c. Check
for
a
broken
meter
glass
and
( 4 ) Remove
the
outer
fiberboard
carton
broken
lamps.
from the wooden packing case.
d. Check
the
ac
line
cord,
test
leads,
and
rubber gasket around the edge of the cover
( 5 ) Open the outer fiberboard carton and
remove
the
inner
fiberboard
carton.
(except
on
TV-7/U)
for
signs
of
deterioration.
Section II. CONTROLS AND INDICATORS
10. General
Function
Switch or control
Improper
setting
of
the
FILAMENT
VOLT-
Removes  voltage
OFF:
AGE
switch
6)
or
incorrect
operation
of
from FILA-
the pushbutton switches may damage the tube
MENT  VOLT-
under test. Be sure that all the controls and
AGE switch.
switches
are
set
properly
before
testing
tubes.
FILAMENT selectors,
Connects filament of tube
left and right (10-
under test to filament volt-
Controls,
Indicators,
and
Jacks
position, 5-section
age supply.
a.
Switches
and
Controls.
rotary switches)
When set in one of positions
GRID selector (10-po-
Function
Switch or control
1-9, connects control grid
sition, 5-section
of tube under test to bias
rotary switch)
Connects ac
ON:
POWER switch . . . . . . . . . . . .
and signal voltages.
power to test
When set in one of positions
PLATE selector (10-
set.
1-9, connects plate of tube
position,  5-section
Removes ac
OFF:
under test to plate voltage
rotary switch)
power from
supply.
test set.
When set in one of positions
SCREEN selector (10-
Provides an 18-step selection
FILAMENT VOLT-
position,  5-section
1-9, connects screen grid of
of filament voltages from
AGE (20-position
rotary switch)
tube under test to screen
0.6-volt to 117 volts ac.
rotary switch)
voltage supply.
Enables ballast
BLST.:
When set in one of positions
C A T H O D E selector
tubes to be
(10-position  rotary
1-9, connects cathode of
tested for con-
switch, 0-position
tube under test to desired
tinuity and
open)
test circuit.
supplies volt-
age to certain
When set in one of positions
SUPPRESSOR selector
rectifier tubes
(10-position  rotary
1 - 9 , connects suppressor
for emission
switch, 0-position
grid of tube under test to
tests.
desired test circuit.
open)

Privacy Statement - Press Release - Copyright Information. - Contact Us