Procedure
Up
TM-11-6625-2616-14 Digital Voltmeter AN/GSM-64A Manual
Next
Procedure

TM 11-6625-2616-14
8-7. Isolation Test
a. Test Equipment. DC voltage standard, John
c. Test Connections and Conditions.
Fluke Model 332A (FSN 6625­239­8924), or
(1) Connect the equipment as shown in fig-
equivalent.
ure 8-4.
b. Materials. 1K ohm, 1/2-watt resistor and
(2) All reference to switch settings refer to
either a 1.5-volt flashlight. cell or a 1.3-volt
the AN/GSM­64A.
mercury cell.
Figure 8-4. Connections for isolation test No. 1.