Tb 9-6685-331-50
(7) Press down arrow at INP? until MX+B appears in the display. Press ENTER
key. Press ENTER key again when M is displayed.
(8) Numbers will appear in the center display window and the high mantissa for
M, indicated by MANH, appears in the right display. Press CE key until all numbers
have been deleted from the center window.
(9) Press 1; press and release SHIFT and the 8 key to display 1 and the decimal
point (1.).
(10) Press 00000. The center display should be 1.00000. This is the temporary
mantissa high number for M. Press ENTER key.
(11) The mantissa low MANL will appear in the right window while numbers are
displayed in center window. Press CE key until the numbers are cleared. Replace with
zeros (000000). Press ENTER key.
(12) Change the exponent EXPO to 00 (if the exponent has a negative sign, press
the SHIFT and 1 keys to clear) and then press ENTER.
(13) Press ENTER key to view the new value for M (1.00000). The exponent will
be (E 00). Press ENTER key.
(14) B appears in the right window. Press ENTER key to continue.
(15) Press CE key to clear the existing numbers for the B MANH (if the value has
a negative sign, press SHIFT and 1 keys to clear) and then press ENTER. Add a zero
(0) and a decimal point then zero fill until 0.00000 shows for MANH. Press ENTER
key.
(16) Press CE key to clear the present number for MANL and add zeros (0) until
000000 is displayed for MANL. Press ENTER key.
(17) Change exponent EXPO and sign to
00 and press ENTER key. Press
ENTER key again at the E-00 display.
(18) Temporary mantissas of 1.00000 and 000000 for M and B are now installed
in the A1012 (TI).
(19) Press down arrow at the 99999 +FSC display until OLD? appears in the
right window. Press EXIT key and confirm by pressing YES key.
(20) Remove the configuration panel
b. Adjustments. No adjustments are required.
7