Click here to make tpub.com your Home Page

Page Title: Figure 11. Insulation resistance and resistance check.
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Back
Insulation Resistance
Up
TB-9-4920-454-35 Tester Exhaust Gas Temperature Howell Instruments Inc. Model BH112JB-( ) Manual
Next
Resistance Check

TB 9-4920-454-35
Figure 11. Insulation resistance and resistance check.
(4) Set resistance standard for 0 Ω.
(5) Set INSULATION CHECK switch to RX100. If INSULATION RESISTANCE meter
does not indicate 0, perform b (l) below.
(6) Adjust resistance standard for an indication of 100 on INSULATION RESISTANCE meter.
Resistance standard will indicate between 9.0 and 11 kΩ.
(7) Set resistence standard to its lowest value. Set INSULATION CHECK switch
to RX1000. If INSULATION RESISTANCE meter does not indicate 0, perform b (2)
below.
(8) Adjust resistance standard for an indication of 100 on INSULATION CHECK
meter. Resistance standard will indicate between 90 and 110 kΩ.
b. Adjustments
(1) Adjust R30 (fig. 12) for an INSULATION CHECK meter indication of 0 (R).
(2) Adjust R27 (fig. 12) for an INSULATION RESISTANCE meter indication of 0 (R).