Engine Oil Press No. 1 and No. 2
Up
TB-9-4920-361-24 Vertical Display System Line Test Set Cavadian Marconi Model 476-853 and Bench Test Set Canadian Marconi Model 476-854 Manual
Next
Xmsn Oil Press

TB 9-4920-361-24
(4) Set ON-OFF-SIM ONLY switch to SIM ONLY. If multimeter does not indicate
between 3.447 and 3.735 V ac, perform b (1) through (4) below.
(5) Set ENGINE OIL PRESS NO. 1 HI/LO switch to HI. Multimeter will indicate
between 2.770 and 3.058 V ac.
(6) Set ENGINE OIL PRESS NO. 1 CAL/NOR switch to NOR and adjust
ENGINE OIL PRESS NO. 1 variable control from fully ccw to fully cw. If multimeter does
not indicate from more than 3.447 to less than 2.770 V ac, perform b (1) through (3) and (5)
and (6) below.
(7) Set ON-OFF-SIM ONLY switch to OFF and calibrator to STBY.
(8) Connect equipment as shown in figure 3, connection A, for connector No. 2.
(9) Repeat (2) through (7) above except use ENGINE OIL PRESS NO. 2 controls.
If not within tolerance in (4) above, perform b (1) through (3) and (7) below. If not in
tolerance in (6) above, perform b (1) through (3) and (8) and (9) below.
b. Adjustments
(1) Set autotransformer and dc power supply to OFF, and calibrator to STBY.
(2) Remove pressure board A2 (fig. 4) and reinstall, using extender board.
Figure 4. Simulator unit - internal left view.
(3) Set autotransformer, dc power supply, and calibrator power to ON.
(4) Adjust R5 (fig. 4) for a 3.591 V ac indication on multimeter (R).
(5) Turn ENGINE OIL PRESS NO. 1 variable control fully ccw.
(6) Adjust R1 (fig. 4) for a 3.591 V ac indication on multimeter (R).
(7) Adjust R22 (fig. 4) for a 3.591 V ac indication on multimeter (R).
(8) Turn ENGINE OIL PRESS NO. 2 variable control fully ccw.
(9) Adjust A2R18 (fig. 4) for a 3.591V ac indication on multimeter (R).
13