Test instrument parameters
Performance specifications
Vehicle test meter (VTM)
Dc voltage
Range  0 to 0.5V dc
Accuracy: ±6% of FS
Range  0.5 to 4.5 V dc
Accuracy: ±3% of FS
Range:  4.5 to 45 V dc
Accuracy: ±1% of FS
Range:  0Ω to 3000
Resistance
Accuracy: ±(3% of indication +0.3% of FS)
Range:  3000Ω to 40,000
Accuracy: ±(3% of indication +0.5% of FS)
Dc current  1
Range:  0 to 20 A dc
Accuracy: ±7% of input
±2% of FS
Range:  0 to 150 A dc
Accuracy: ±7% of input
±0.7% of FS
Range:  0 to 1500 A dc
Accuracy: ±7 to 8% of input
±0.5% of FS
Ac current
Range:  5 to 70 A
Accuracy:±(7.0% of indication +2.0% of FS)
(Frequency range: 40 to 500 Hz)
Range:  70 to 700 A
Accuracy: ±7.0% of indication +0.65% of FS)
Ac voltage
Range:  0 to 35 V
Accuracy: ±(4.0% of indication +0.5% of FS)
(Frequency range: 1 0 to 500 Hz)
Frequency
Range:  40 to 500 Hz
Accuracy: ±7% of input
±0.65% of FS
Pressure
Range:  0 to 25 psia
0 to 1000 psia
Accuracy: ±(2.5% of indication +1.5% of FS)
Vacuum
Range:  0 to 30 inHg
Accuracy: ±3.5% of input
±1.5% of FS
RPM
Range:  50 to 5000 rpm
Accuracy: ±0.5% of FS
Controllable interface box
10 V channel
Range: 9.5 V dc
Accuracy: ±0.2 V
10 V differential
Range: 9.5 V dc
Accuracy: ±0.2 V
Frequency
Range:  400 Hz
Accuracy: ±20 Hz
See footnotes at end of table.