Click here to make tpub.com your Home Page

Page Title: DEPARTMENT OF THE ARMY TECHNICAL BULLETIN
Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Up
TB-55-6625-726-35 Calibration Procedure for Insulation Breakdown Test Set Bendix Model 13700-1-C Manual
Next
Section I. IDENTIFICATION AND DESCRIPTION

DEPARTMENT OF THE ARMY TECHNICAL BULLETIN
CALIBRATION PROCEDURE FOR
INSULATION BREAKDOWN TEST SET,
BENDIX MODEL, 13700-1-C
FEDERAL STOCK NUMBER 6625-765-9079
Headquarters, Department of the Army, Washington, D. C.
29 April 1974
WARNING
PRECAUTIONARY DATA
Personnel performing operations involving instructions, procedures and practices which are included
or implied in this technical bulletin shall observe the following instructions.  Disregard of these
warnings and precautionary information can cause serious injury,-death, or an aborted mission. HIGH
VOLTAGE. High voltage is used during the performance of this procedure. Death on contact may
result if personnel fail to observe safety precautions.
Paragraph
Page
IDENTIFICATION AND DESCRIPTION
Test Instrument Identification .................................................................1-1
Calibration Description ............................................................................1-2
Forms and Records..................................................................................1-3
Reporting of Errors ..................................................................................1-4
EQUIPMENT REQUIREMENTS
Equipment Required ................................................................................2-1
Accessories Required..............................................................................2-2
PRELIMINARY OPERATIONS
Preliminary Instructions ..........................................................................3-1
Equipment Setup......................................................................................3-2
CALIBRATION PROCESS
AC Voltmeter (Low Range) ......................................................................4-1
AC Voltmeter (High Range) .....................................................................4-2
AC Current Meter......................................................................................4-3
Final Procedure ........................................................................................4-4
*This bulletin supersedes TB 55-6625-726-35, 15 April 1971.
1