Next
Table 5.0 Voltage Source Test DC

TB 55-4920-429-35
Set TI SELF TEST switch to the OFF position.
(9)
b.
Adjustments.
(1) Remove screws from case and remove panel assembly.
(2) Adjust TI DC power supply PS5 for +5 vdc on digital
multimeter (R).
(3) Adjust TI DC power supply PS3 for +15 vdc on digital
multimeter (R).
Repeat performance check 9a(8) above for this
switch position.
(4) Adjust TX DC power supply PS4 for -15 vdc on digital
multimeter (R).
Repeat performance check 9a(8) above for this
switch position.
(5) Adjust TI DC power supply PS2 for -15 vdc on digital
multimeter (R).
Repeat performance check 9a(8) above for this
switch position.
(6) Adjust TI DC power supply PS1 for +15 vdc on digital
multimeter (R).
Repeat performance check 9a(8) above for this
switch position.