SECTION IV CALIBRATION PROCESS
Up
TB-55-4920-429-35 Calibration Procedure for Advanced Flight Control System Line Set P/N 145G0009-1 Manual
Next
Adjustments.

TB 55-4920-429-35
9.
Power Supplies Voltages.
Performance Check.
a.
(1) Connect digital multimeter
(A3) leads (B4) and (B5)
to the TI HI/LO test point jacks position.
Set TI 115 vac POWER switch to ON.
(2)
Set TI 28 vdc POWER switch to ON.
(3)
(4) Set TI METER SOURCE to OFF and SELF TEST Switch to
OFF position.
TI will indicate 0000 ± 0005.
Set TI METER SOURCE to SELF TEST and SELF TEST Switch
(5)
to DISPLAY position.
TM DMM will indicate +.8.8.8.8.
Digital multimeter
Set TI SELF TEST to DM +5 vdc.
(6)
will indicate between 4.90 and 5.10 vdc.
If not, perform b(1)
and b(2) below.
TI DMM will indicate between 4.90 and 5.10 vdc.
(7)
(8) Set TI SELF TEST switch to each switch position as
listed in tables 5.0 and 6.0.
Digital multimeter and TI DMM
indicator will indicate within the limits specified.
13