SECTION II EQUIPMENT REQUIREMENTS

TB 55-4920-428-35
Table 2. Calibration Description (Modified Test Set) (Continued)
Performance Specifications
Test Instrument Parameters
115 to 117 vac 50-60 Hz
Power Input Requirements
5.0 Vdc
Range:
Bite Voltages
±0.25 vdc
Accuracy:
12.0 vdc
Range:
±0.25 vdc
Accuracy:
-12.0 vdc
Range:
±0.25 vdc
Accuracy:
19.5 vdc
Range:
±0.25 vdc
Accuracy:
-19.5 vdc
Range:
±0.25 vdc
Accuracy:
13.07 vac
Range:
±0.13 vac
Accuracy
1.0 vac
Range:
SAS1 Self, Cross
±0.05 vdc
Accuracy:
SAS2 Self, Cross Voltages
1.0 vac
Range:
SAS1 or SAS3
±.05 vac
Accuracy:
LVDT Voltages
2.0 vac
Range:
±.05 vac
Accuracy:
0.4 vac
Range:
±.02 vac
Accuracy:
-50 to + 50 uadc
Range:
Nullmeters
±5.0 uadc
Accuracy: