SECTION I IDENTIFICATION AND DESCRIPTION
Up
TB-55-4920-428-35 Calibration Procedure for CH-47 Integrated Lower Control Actuator (ILCA) Bench Test Set P/N 145GS278-1 Manual
Next
Table 1. Calibration Description (Test Set Not Modified) (Continued)

TB 55-4920-428-35
Table 1. Calibration Description (Test Set Not Modified)
Test Instrument Parameters
Performance Specifications
Power Input Requirements
115 to 117 vac 50-60 Hz
DC Power Supply PS2
Range:
28.0 vdc
Accuracy:
±0.5 vdc
DC Power Supply PS1
+ 12.0 vdc
Range:
Accuracy:
±0.5 vdc
-12.0 vdc
Range:
Accuracy:
±0.5 vdc
AC Power Supply PS3
Range;
13.0 vac
Accuracy:
±0.5 vac
Frequency P/O PS3
Range:
400 Hz
Accuracy:
±5.0 Hz
Bite Terminal Voltages
Range:
5.0 vdc
Accuracy:
±0.3 vdc
Range:
12.0 vdc
Accuracy:
0.5 vdc
Range:
-12.0 vdc
Accuracy:
±0.5 vdc
20.0 vdc
Range:
Accuracy:
±1.0 vdc
-20.0 vdc
Range:
Accuracy:
±1.0 vdc
13.0 vdc
Range:
Accuracy:
±0.5 vdc
.9 vdc
Range:
Bite SAS1 Self, Cross
±0.1 vdc
Accuracy:
SAS2 Self, Cross Voltages
18.0 vdc or -18.0 vdc
Range:
Valve Servo Voltage
±2.0 vdc
Accuracy:
-50 to +50 uadc
Range:
Nullmeters
±5.0 uadc
Accuracy:
4