Click here to make tpub.com your Home Page

Page Title: Section III. PRELIMINARY OPERATIONS
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Back
Section II. EQUIPMENT REQUIREMENTS
Up
TB-55-4920-389-34 Calibration Procedure for Test Stand Ignition Magnet to Hydraulic Technology Inc. Models 6990A Manual
Next
Tachometer Indicator.

TB 55-4920-389-34
When necessary, these items may be substituted by equivalent items unless specifically prohibited.
Table 2-2. Accessories Required
Accessory Identification1
Item
Common Name
B1
Test Lead
30-in., lead No. 10 AWG with spade lug
terminal to pin tip terminal (red)
B2
Test Lead
30-in., lead No. 10 AWG with spade lug
terminal to pin tip terminal (black)
1
See footnote under table 2-1.
Section III. PRELIMINARY OPERATIONS
3-1. Preliminary Instructions.
a. The instructions outlined in this section are preparatory to the calibration process. Personnel should become
familiar with the entire bulletin before beginning the calibration.
b. Items of equipment used in this procedure are referenced within the text by common name and item
identification number as listed in tables 2-1 and 2-2. For the identification of equipment referenced by item number
prefixed with A, see table 2-1; and for prefix B, see table 2-2.
3-2. Equipment Setup.
WARNING
HIGH ELECTRICAL CURRENT is utilized within the Test Instrument during performance
of this procedure. OBSERVE UUT start and stop procedures pertinent to the Test
Instrument being calibrated to prevent possible damage to equipment and/or injury to
personnel.
a. Adjust the test instrument tachometer indicator and AC ammeter for mechanical zero by means of screw
driver slot located at lower front of indicator.
b. Set test instrument SPEED ADJUST controls both in the fully counterclockwise (CCW) position.
c.
Set test instrument DRIVE ROTATION switch to clockwise (CW) position.
d. Mark test instrument generator center drive shaft with a piece of black tape.
3