Page Title: Table 4. Pressure Gage Performance Limits
Back | Up

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Back
 Equipment Setup
Up
TB-3-6665-312-50 Calibration Procedure for Tester Airflow Resistance Q179 Manual

b.
Adjustments. No adjustments can be made.
manometer (A2) to atmospheric pressure.
(6) Disconnect the test equipment.
Figure 3. PRESSURE gage performance check, equipment setup.
Table 4. Pressure Gage Performance Limits
Scale major Division Indications
Acceptable Manometer Indications
(inches of water)
Min.
Max.
1.06
0.94
1
2.06
1.94
2
3.06
2.94
3
(3) Repeat (2) above for " 10" on the AIR
9. AIR FLOW Gage. a Performance Check.
FLOW gage.  Flowmeter (Al) must indicate between
(1) Connect the test equipment as shown in
32.6 and 37.4.
(4) Release the TEST switch.
(2) Adjust AIR FLOW VALVE to obtain a
(5) Disconnect the test equipment.
reading of "4" on the AIR FLOW gage. Flowmeter (Al)
b.  Adjustments. No adjustments can be made.
must indicate between 82.6 and 87.4.
Figure 4. AIR FLOW gage performance check, equipment setup.
the TI does not indicate within the limits specified in
10. Final Procedure. a. Deenergize and disconnect
paragraph 8a or 9a, annotate and affix DA Form 2417
all equipment.
(Unserviceable or Limited Use) tag.
b.  In accordance with TM 38-750, annotate and
affix DA Label 80 (US Army Calibration System). When
4