![]() ![]() CHANGE 1
DEPARTMENT OF THE ARMY TECHNICAL BULLETIN
CALIBRATION PROCEDURE FOR
DIRECTION FINDER SET TEST SET
AN/ARM-93
(NSN 6625-00-999-6081)
Headquarters, Department of the Army, Washington, DC
20 June 1979
TB 11-6625-821-35, 9 August 1973 is changed as follows:
The title of the bulletin is changed as shown above.
Communications and Electronics Materiel Readiness Command, ATTN: DRSEL-ME-MQ,
Fort Monmouth, NJ 07703."
"Adjustments to be
annotated on DA Form 2416 are followed by (R) in this procedure."
Table 1A is superseded as follows:
A - Authorized calibration equipment
Common name
Minimum use specifications
Calibration equipment
FREQUENCY METER
AN/USM-207 or SD-1037M2
Range: 400 Hz ±10%
VOLTMETER
ME-202/U or Dana 5700 series
Range: 30 Volts ac ±0.5%
VOLTMETER RF
For a null indication
ME-20/U or HP 400 series
OSCILLOSCOPE
For lissajous pattern
AN/USM-281 or HP 180 series
SIGNAL GENERATOR
Range: to 1700 kHz
AN/URM-25 or equal
POWER SUPPLY
Range: 27.5 Volts dc
CS36CR30 or equal
Banana plug to banana plug lead
2 required
Banana plug to pin adapter
2 required
Banana plug to alligator clip
Quantity as required
Fabricated cable (fig. 1)
Some modification of this cable is permissible as to size, length,
and loose ends.
PIN: 010598-001
|
|