DEPARTMENT OF THE ARMY TECHNICAL BULLETIN
Up
TB-11-6625-434-12-1 Preventive Maintenance Checks and Services Test Set Armature TS-965/U Manual
Next
APPENDIX REFERENCES

serviceability, the charts indicate what to check, how to
higher echelon maintenance or repair is required.
check, and the normal conditions; the References
Records and reports of these checks and services must
be made in accordance with the requirements set forth in
column lists the manuals that contain detailed repair or
TM 38750.
replacement procedures.
If the defect cannot be
remedied by performing the corrective actions listed,
6.
Daily Preventive Maintenance Checks and Services Chart.
Sequence
Item
Procedure
References
No.
1
Completeness ------------
See that the equipment is complete.
2
Cleanliness ----------------
Clean the exterior surfaces -----------------------------------
3
Operation ------------------
Operate the equipment according to the instruc-
tion book packed with the equipment. Be alert
for any unusual performance or condition.
7.
Weekly Preventive Maintenance Checks and Services Chart.
Sequence
Item
Procedure
References
No.
1
Wires -----------------------
Inspect wires for chafed, cracked, or frayed in-
sulation.
2
Exterior ---------------------
Inspect exposed surfaces for rust and corrosion.
Touch up paint as required.
8.
Quarterly Preventive Maintenance Checks and Services Chart.
Sequence
Item
Procedure
References
No.
1
Publications ---------------
See that all publications are complete, serviceable,----
DA Pam 310-4.
and current.
2
Modifications --------------
Check DA Pam 3104 to determine if new applicable---
TM 38-750 and DA
MWO's have been published. All URGENT MWO's
Pam 310-4.
must be applied immediately. All NORMAL MWO's
must be scheduled.
3
Spare parts ----------------
Check all spare parts (operator and organizational)
for general condition and method of storage. There
should be no evidence of overstock, and
shortages must be on valid requisitions.
c.  If necessary, dampen the cloth with water;
9.
Cleaning. Inspect the exterior of the armature
use mild soap for more effective cleaning.
test set. The exterior surfaces should be clean, and free
of dust, dirt, grease, and fungus.
a.  Remove dust and loose dirt with a clean
10.
Touchup Painting Instructions. Remove rust
soft cloth.
and corrosion from metal surfaces by lightly sanding
them with fine sandpaper. Brush two thin coats of paint
Warning: Cleaning compound is flammable
on the bare metal to protect it from further corrosion.
and  its  fumes  are  toxic.
Provide  adequate
Refer to the applicable cleaning and refinishing practices
ventilation. Do not use near a flame.
specified in TM 9-213.
b.  Remove grease, fungus, and ground-in dirt
from the equipment; use a cloth dampened (not wet) with
Cleaning Compound (Federal stock No. 7930-385-9542).
AGO 7160A
2