Click here to make tpub.com your Home Page

Page Title: DVM Logic Module A5A1 Calibration
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Back
Detector/AmplifierA3A2Calibration
Up
TB-11-6625-2974-30 Calibration Procedures for Radar Test Set Group OQ-270/APS-94F Manual
Next
DVM Logic Minor Adjustment.

TB 11-6625-2974-30
Figure 4-6. Detector/Amplifier Adjustment Location.
(3) Disconnect DVM. Remove extender card and
4-4.  DVM Logic Module A5A1 Calibration
reinstall DVM logic module in card cage.
a.
Antenna Detection Performance Check.
(4) Remove 50-ohm termination from RF IN J3
(1)  Connect DVM to pin 21 (+) and pin 1 (-) of
connector.
extender card.
c.
DVM Logic Performance Check.
(2)  Observe DVM. Reading should be 0.0 + 0.Vdc.
(1)  Set METER SELECT switch (fig.4-1) to EXT
If the standard is met, perform step 3. If not, go
INPUT.
to subparagraph b (below) for adjustment.
(2) Connect a jumper wire between the two front
(3) Set STE PRIME POWER AC and DC switches
panel EXTERNAL INPUT jacks.
to OFF.
(3) Set STE PRIME POWER AC and DC switches
(4) Disconnect DVM. Remove extender card and
to ON.
reinstall DVM logic module in card cage.
(4)  Observe front panel METER. Display  should
(5)  Remove 50-ohm termination from RF IN J3
be -00.
connector.
(5) Remove jumper wire from EXTERNAL INPUT
b.
Antenna Detection Adjustment.
jacks.
(1)  Adjust A5A1-R52 (fig.-7) to obtain a reading of
(6) Using a DVM, adjust an external power supply
0.+ 0.1 Vdc on DVM.
for +30. + 0.05 V.
(2) Set STE PRIME POWER AC and DC switches
(7) Connect  the  power  supply  outputs  to
to OFF.
EXTERNAL INPUT red (+) and gray (-) jacks.
4-8

Privacy Statement - Press Release - Copyright Information. - Contact Us