Page Title: Table 4. Frequency Dial Check
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Back
SECTION III. PRELIMINARY OPERATIONS
Up
TB-11-6625-2841-35 Calibration Procedure Signal Generator Polard Model 1709 Manual
Next
Table 5. Power Output Check (10.0 to 12.4 and 12.4 to 15.0 GHz)

volts and back to 115 volts.
Frequency counter will
(8)  Adjust FREQUENCY GHZ control to
indicate within  0.008 percent of indication recorded in
positions listed in table 4.
If frequency counter
(6) above.
indications are not within limits specified, perform b
below.
Table 4. Frequency Dial Check
Frequency counter indications (GHz)
Test instrument
FREQUENCY GHz
control settings
Min
Max
4.50
9.955
9.045
5.50
10.945
11.055
6.50
12.935
13.065
7.50
14.925
15.075
8.40
16.716
16.884
b
Adjustments (fig. 1)
Figure 1. Signal source--top view.
4