DEPARTMENT OF THE ARMY TECHNICAL BULLETIN
Up
TB-11-6625-2713-50 Calibration Procedure for Oscilloscope AN/USM-296A Manual
Next
TABLE OF CONTENTS

Paragraph 9b(1) and (2) are superseded as follows:
(1) Adjust A2A3R1 (fig. 2) for 0.0 volts.
(2) Adjust A2A6R56 (fig. 1) for 0.0 volts.
Page 6, table 4 is superseded as follows:
Test instrument
Ac calibrator indications
VOLTS/DIV
(rms)
switch settings
Minimum
Maximum
.01
13.857
mV
14.423
mV
.02
27.714
mV
28.846
mV
.05
69.286
mV
72.120
mV
.1
0.13857 V
0.14423 V
.2
0.27714 V
0.22846 V
.5
0.69286 V
0.72120 V
1
1.3857  V
1.4423  V
2
2.7714  V
2.8846  V
5
6.9286  V
7.2120  V
10
13.857
V
14.423
V
Page 7, table 5, first column, line 5. ".51" is changed to read: 51.
Paragraph 13b, line 1. "A1A549" is changed to read: A1A5R49, and (R) is added at
the end of the sentence.
Paragraph 14a(3), line 2. "10 MHz" is changed to read: 1MHz.
Page 8, paragraph 15a(4), line 2. "0.3" is changed to read: 0.5.
Paragraph 16a(3), line 2. "-0.01 and +0.01" is changed to read: +0.64 and +0.66.
Paragraph 16b(2), line 2. "0.00" is changed to read: +0.65.
Paragraph 16b(3), line 1. "+0.25" is changed to read: -0.25.
Page 9, paragraph 16B(4), line 1. "A1A1A2R12" is changed to read: A1A2R12.
Page 11, table 6, first column, lines 1 through 9. "SEC" is changed to read: µSEC.
Table 6, second column, lines 2 through 9. "pS" is changed to read: µS.